www.netzsch-thermal-analysis.com - NETZSCH Analyzing & Testing

Are you over 18 and want to see adult content?

6

More Annotations

星乃珈琲店 オフィシャルサイト

星乃珈琲店 オフィシャルサイト

https://hoshinocoffee.com
Profile Image
Maria Johnson
2021-06-06 13:01:16
星乃珈琲店 オフィシャルサイト

星乃珈琲店 オフィシャルサイト

https://hoshinocoffee.com

Are you over 18 and want to see adult content?

Student Hut

Student Hut

https://studenthut.com
Profile Image
Maria Johnson
2021-06-06 13:01:16
Student Hut

Student Hut

https://studenthut.com

Are you over 18 and want to see adult content?

Archives of Medicine and Health Sciences - Free full text articles from Arch Med Health Sci

Archives of Medicine and Health Sciences - Free full text articles from Arch Med Health Sci

https://amhsjournal.org
Profile Image
Maria Johnson
2021-06-06 13:01:17
Archives of Medicine and Health Sciences - Free full text articles from Arch Med Health Sci

Archives of Medicine and Health Sciences - Free full text articles from Arch Med Health Sci

https://amhsjournal.org

Are you over 18 and want to see adult content?

Your Location

Your Location

https://pl.2day.uk
Profile Image
Maria Johnson
2021-06-06 13:01:17
Your Location

Your Location

https://pl.2day.uk

Are you over 18 and want to see adult content?

A complete backup of https://avropa.info

A complete backup of https://avropa.info

https://avropa.info
Profile Image
Maria Johnson
2021-06-06 13:01:17
A complete backup of https://avropa.info

A complete backup of https://avropa.info

https://avropa.info

Are you over 18 and want to see adult content?

yoursun.com - Florida`s Local News

yoursun.com - Florida`s Local News

https://sun-herald.com
Profile Image
Maria Johnson
2021-06-06 13:01:18
yoursun.com - Florida`s Local News

yoursun.com - Florida`s Local News

https://sun-herald.com

Are you over 18 and want to see adult content?

6
pfSense® - World`s Most Trusted Open Source Firewall

pfSense® - World`s Most Trusted Open Source Firewall

https://pfsense.com
Profile Image
Maria Johnson
2021-06-06 13:01:18
pfSense® - World`s Most Trusted Open Source Firewall

pfSense® - World`s Most Trusted Open Source Firewall

https://pfsense.com

Are you over 18 and want to see adult content?

Rugged Wool Caps & Accessories Since 1903 - Stormy Kromer®

Rugged Wool Caps & Accessories Since 1903 - Stormy Kromer®

https://stormykromer.com
Profile Image
Maria Johnson
2021-06-06 13:01:19
Rugged Wool Caps & Accessories Since 1903 - Stormy Kromer®

Rugged Wool Caps & Accessories Since 1903 - Stormy Kromer®

https://stormykromer.com

Are you over 18 and want to see adult content?

Painted Teacup - Essential Oils, Mental Health & Chronic Illness

Painted Teacup - Essential Oils, Mental Health & Chronic Illness

https://paintedteacup.com
Profile Image
Maria Johnson
2021-06-06 13:01:20
Painted Teacup - Essential Oils, Mental Health & Chronic Illness

Painted Teacup - Essential Oils, Mental Health & Chronic Illness

https://paintedteacup.com

Are you over 18 and want to see adult content?

Wesserling Park - Découvrez la cité textile datant du 19ème siècle !

Wesserling Park - Découvrez la cité textile datant du 19ème siècle !

https://parc-wesserling.fr
Profile Image
Maria Johnson
2021-06-06 13:01:20
Wesserling Park - Découvrez la cité textile datant du 19ème siècle !

Wesserling Park - Découvrez la cité textile datant du 19ème siècle !

https://parc-wesserling.fr

Are you over 18 and want to see adult content?

Hacked By TH4UF4N – Im Fine --)

Hacked By TH4UF4N – Im Fine --)

https://yuvavibe.in
Profile Image
Maria Johnson
2021-06-06 13:01:22
Hacked By TH4UF4N – Im Fine --)

Hacked By TH4UF4N – Im Fine --)

https://yuvavibe.in

Are you over 18 and want to see adult content?

Design made in Germany

Design made in Germany

https://designmadeingermany.de
Profile Image
Maria Johnson
2021-06-06 13:01:24
Design made in Germany

Design made in Germany

https://designmadeingermany.de

Are you over 18 and want to see adult content?

1

Favourite Annotations

Dr. Carolyn Dean MD ND – The Doctor of the Future

Dr. Carolyn Dean MD ND – The Doctor of the Future

drcarolyndean.com
Profile Image
Maria Johnson
2020-05-06 01:42:12
Dr. Carolyn Dean MD ND – The Doctor of the Future

Dr. Carolyn Dean MD ND – The Doctor of the Future

drcarolyndean.com

Are you over 18 and want to see adult content?

Finanssiala ry

Finanssiala ry

finanssiala.fi
Profile Image
Maria Johnson
2020-05-06 01:42:41
Finanssiala ry

Finanssiala ry

finanssiala.fi

Are you over 18 and want to see adult content?

Colleges of Medicine, Pharmacy & Graduate Studies - NEOMED

Colleges of Medicine, Pharmacy & Graduate Studies - NEOMED

neomed.edu
Profile Image
Maria Johnson
2020-05-06 01:42:58
Colleges of Medicine, Pharmacy & Graduate Studies - NEOMED

Colleges of Medicine, Pharmacy & Graduate Studies - NEOMED

neomed.edu

Are you over 18 and want to see adult content?

DOMECIL - Tech-Talkies

DOMECIL - Tech-Talkies

domecil.de
Profile Image
Maria Johnson
2020-05-06 01:43:09
DOMECIL - Tech-Talkies

DOMECIL - Tech-Talkies

domecil.de

Are you over 18 and want to see adult content?

Организация Объединенных Наций в Беларуси

Организация Объединенных Наций в Беларуси

un.by
Profile Image
Maria Johnson
2020-05-06 01:43:26
Организация Объединенных Наций в Беларуси

Организация Объединенных Наций в Беларуси

un.by

Are you over 18 and want to see adult content?

55 Plus Mature Asian Pussy. . ASIAN PORN Mature Hd. . Mature Garters Orgy Stockings Sucking. . . . Mature Chubby Lesbian Pussy S

55 Plus Mature Asian Pussy. . ASIAN PORN Mature Hd. . Mature Garters Orgy Stockings Sucking. . . . Mature Chubby Lesbian Pussy S

tatiltinereem.gq
Profile Image
Maria Johnson
2020-05-06 01:43:37
55 Plus Mature Asian Pussy. . ASIAN PORN Mature Hd. . Mature Garters Orgy Stockings Sucking. . . . Mature Chubby Lesbian Pussy S

55 Plus Mature Asian Pussy. . ASIAN PORN Mature Hd. . Mature Garters Orgy Stockings Sucking. . . . Mature Chubby Lesbian Pussy S

tatiltinereem.gq

Are you over 18 and want to see adult content?

4
Toerisme Vlaanderen - Ondersteuning -br- voor vakantiemakers

Toerisme Vlaanderen - Ondersteuning -br- voor vakantiemakers

toerismevlaanderen.be
Profile Image
Maria Johnson
2020-05-06 01:43:41
Toerisme Vlaanderen - Ondersteuning -br- voor vakantiemakers

Toerisme Vlaanderen - Ondersteuning -br- voor vakantiemakers

toerismevlaanderen.be

Are you over 18 and want to see adult content?

Anwalt suchen und finden bei anwalt.de

Anwalt suchen und finden bei anwalt.de

anwalt.de
Profile Image
Maria Johnson
2020-05-06 01:44:02
Anwalt suchen und finden bei anwalt.de

Anwalt suchen und finden bei anwalt.de

anwalt.de

Are you over 18 and want to see adult content?

ПРОМБУК.РФ - Фотокниги и Выпускные альбомы

ПРОМБУК.РФ - Фотокниги и Выпускные альбомы

xn--90asehegy.xn--p1ai
Profile Image
Maria Johnson
2020-05-06 01:44:22
ПРОМБУК.РФ - Фотокниги и Выпускные альбомы

ПРОМБУК.РФ - Фотокниги и Выпускные альбомы

xn--90asehegy.xn--p1ai

Are you over 18 and want to see adult content?

Chea Sports

Chea Sports

cheapmlb-jerseys.us
Profile Image
Maria Johnson
2020-05-06 01:44:34
Chea Sports

Chea Sports

cheapmlb-jerseys.us

Are you over 18 and want to see adult content?

New Mexico Compilation Commission – Official Legal Publisher of State of New Mexico

New Mexico Compilation Commission – Official Legal Publisher of State of New Mexico

nmcompcomm.us
Profile Image
Maria Johnson
2020-05-06 01:44:46
New Mexico Compilation Commission – Official Legal Publisher of State of New Mexico

New Mexico Compilation Commission – Official Legal Publisher of State of New Mexico

nmcompcomm.us

Are you over 18 and want to see adult content?

Kestrel Games

Kestrel Games

kestrelgames.com
Profile Image
Maria Johnson
2020-05-06 01:44:54
Kestrel Games

Kestrel Games

kestrelgames.com

Are you over 18 and want to see adult content?

4

Text

GABOMETER - NETZSCH ANALYZING & TESTING The testing instruments of the DMA GABO EPLEXOR ® series up to ±500 N enable the dynamic mechanical (or static) characterization of a wide range of different materials including elastomers and polymers, composites, metals, glasses, ceramics, biomaterials and foods, adhesives, and liquids. DMA GABO EPLEXOR ® Ultra-High Force Series up

to 6000 N.

LOI – OXYGEN INDEX ANALYZER Testing system for determining the burning behavior of plastics by oxygen index at ambient temperature in accordance with ISO 4589-2, DIN 22117 and ASTM D 2863. Compact and lightweight, the device features a high-resolution touch display for intuitive user guidance. The fully automatic calibration and testing functions make it easy to operate DYNAMIC MECHANICAL ANALYSIS (DMA) Dynamic Mechanical Analysis (DMA) is an indispensable tool for determining the visco-elastic properties of materials, mainly polymers. Elastomers, for example, are very rigid below the glass transition temperature (T g) and have a high modulus of elasticity. Above T g, they are flexible and show damping performance.DMA measures the visco-elastic properties during a controlled temperature and LASER FLASH TECHNIQUE (LFA) The LFA 457 MicroFlash ® is the most modern product for the determination of the two thermophysical properties, thermal diffusivity and conductivity, in the range from -125°C to 1100°C. Its compact, vacuum-tight construction, automatic sample changer and functional software guarantee the highest effectiveness for challenging materials testing. DIL 402 EXPEDIS SELECT & SUPREME The dilatometer DIL 402 Expedis Select and Supreme offer state-of-the-art dilatometer technology and are designed for a wide range of sophisticated applications. All instruments of the DIL Expedis series feature the revolutionary NanoEye measuring cell; a new dimension in measuring range and accuracy.. It is the first horizontal dilatometer series on the market which allows for force

DSC 3500 SIRIUS

NETZSCH is the leading manufacturer of high quality DSC instruments or Differential Scanning Calorimeters at attractive prices with easy handling and advanced Software. The cost-effective starter instrument for material characterization. The DSC 3500 Sirius unites state-of-the-art technology with high sensitivity in a robust, easy-to-operate measuring system across a temperature range from

ROSAND RH2000

The Rosand RH2000 capillary rheometer system enables controlled extrusion (by volumetric flow) of a sample through a high precision die of known dimensions, to characterize material flow properties typically under conditions of high force (or pressure) and/or high shear rate. Using the twin bore barrel option and a ‘zero length’

die

TG 209 F3 TARSUS®

TG 209 F3 Tarsus - this easy-to-use thermo-microbalance was developed especially for routine applications in the field of plastics, but also for the chemical industry. It is the ideal starter unit up to 1000°C and, together with the DSC 200 F3 Maia®, represents a cost-effective

overall concept.

GUARDED HOT PLATE (GHP) The Guarded Hot Plate instrument measures the thermal conductivity of insulation products. The GHP principle is based on an absolute measurement method and therefore requires no calibration standards. It offers optimum accuracy in the available temperature range. The hot plate and the guard ring are sandwiched between two specimens of the

same

DEGREE OF CURE

This can easily be measured by means of differential scanning calorimetry (DSC). The degree of curing, α, is the amount of heat converted divided by the reaction enthalpy. α = H/ΔH R. The degree of cure of an already (partially) crosslinked sample can be determined GABOMETER - NETZSCH ANALYZING & TESTING The testing instruments of the DMA GABO EPLEXOR ® series up to ±500 N enable the dynamic mechanical (or static) characterization of a wide range of different materials including elastomers and polymers, composites, metals, glasses, ceramics, biomaterials and foods, adhesives, and liquids. DMA GABO EPLEXOR ® Ultra-High Force Series up

to 6000 N.

LOI – OXYGEN INDEX ANALYZER Testing system for determining the burning behavior of plastics by oxygen index at ambient temperature in accordance with ISO 4589-2, DIN 22117 and ASTM D 2863. Compact and lightweight, the device features a high-resolution touch display for intuitive user guidance. The fully automatic calibration and testing functions make it easy to operate

THERMOGRAVIMETRY

NETZSCH instruments for thermogravimetry have a compact design and are equipped with high-resolution balance systems. The top-loading sample arrangement allows for easy operation and measurement of the temperature directly at the sample. Almost all NETZSCH thermobalances are vacuum-tight and allow for measurement of mass changes under defined atmospheres. DYNAMIC MECHANICAL ANALYSIS (DMA) Dynamic Mechanical Analysis (DMA) is an indispensable tool for determining the visco-elastic properties of materials, mainly polymers. Elastomers, for example, are very rigid below the glass transition temperature (T g) and have a high modulus of elasticity. Above T g, they are flexible and show damping performance.DMA measures the visco-elastic properties during a controlled temperature and QMS 403 AËOLOS QUADRO The Fleshed-Out Design of the QMS 403 Aëolos Quadro for Coupling to TGA, STA, DSC and DIL Systems. The 403 Aëolos Quadro quadrupole mass spectrometer is a new compact mass spectrometer with a heated capillary inlet system for routine analysis of gases and, in particular, volatile decomposition products of thermal analysis. This system is optimized for coupling to differential scanning LASER FLASH TECHNIQUE (LFA) The LFA 457 MicroFlash ® is the most modern product for the determination of the two thermophysical properties, thermal diffusivity and conductivity, in the range from -125°C to 1100°C. Its compact, vacuum-tight construction, automatic sample changer and functional software guarantee the highest effectiveness for challenging materials testing.

ROSAND RH2000

The Rosand RH2000 capillary rheometer system enables controlled extrusion (by volumetric flow) of a sample through a high precision die of known dimensions, to characterize material flow properties typically under conditions of high force (or pressure) and/or high shear rate. Using the twin bore barrel option and a ‘zero length’

die

THERMOREFLECTANCE

Thermoreflectance is a method for determining the thermal diffusivity and thermal conductivity of thin films with thicknesses in the nanometer range. In contrast with the conventional laser flash method, there is no infrared detector used to measure the temperature increase

TG 209 F3 TARSUS®

TG 209 F3 Tarsus - this easy-to-use thermo-microbalance was developed especially for routine applications in the field of plastics, but also for the chemical industry. It is the ideal starter unit up to 1000°C and, together with the DSC 200 F3 Maia®, represents a cost-effective

overall concept.

DEGREE OF CURE

This can easily be measured by means of differential scanning calorimetry (DSC). The degree of curing, α, is the amount of heat converted divided by the reaction enthalpy. α = H/ΔH R. The degree of cure of an already (partially) crosslinked sample can be determined

THERMOGRAVIMETRY

NETZSCH instruments for thermogravimetry have a compact design and are equipped with high-resolution balance systems. The top-loading sample arrangement allows for easy operation and measurement of the temperature directly at the sample. Almost all NETZSCH thermobalances are vacuum-tight and allow for measurement of mass changes under defined atmospheres. RABINOWITSCH CORRECTION The Rabinowitsch (or Weissenberg-Rabinowitsch) correction is applied to get more accurate shear rate values from non-Newtonian materials measured using a capillary flow technique.. The basic shear rate equation for capillary flow is based on Newtonian fluids, where the velocity profile from pressure-driven flow in a capillary is shown to be homogenous (parabolic); however, for non-Newtonian DIL 402 EXPEDIS SELECT & SUPREME The dilatometer DIL 402 Expedis Select and Supreme offer state-of-the-art dilatometer technology and are designed for a wide range of sophisticated applications. All instruments of the DIL Expedis series feature the revolutionary NanoEye measuring cell; a new dimension in measuring range and accuracy.. It is the first horizontal dilatometer series on the market which allows for force

THERMOREFLECTANCE

Thermoreflectance is a method for determining the thermal diffusivity and thermal conductivity of thin films with thicknesses in the nanometer range. In contrast with the conventional laser flash method, there is no infrared detector used to measure the temperature increase

DSC 3500 SIRIUS

NETZSCH is the leading manufacturer of high quality DSC instruments or Differential Scanning Calorimeters at attractive prices with easy handling and advanced Software. The cost-effective starter instrument for material characterization. The DSC 3500 Sirius unites state-of-the-art technology with high sensitivity in a robust, easy-to-operate measuring system across a temperature range from QMS 403 AËOLOS QUADRO The Fleshed-Out Design of the QMS 403 Aëolos Quadro for Coupling to TGA, STA, DSC and DIL Systems. The 403 Aëolos Quadro quadrupole mass spectrometer is a new compact mass spectrometer with a heated capillary inlet system for routine analysis of gases and, in particular, volatile decomposition products of thermal analysis. This system is optimized for coupling to differential scanning GUARDED HOT PLATE (GHP) The Guarded Hot Plate instrument measures the thermal conductivity of insulation products. The GHP principle is based on an absolute measurement method and therefore requires no calibration standards. It offers optimum accuracy in the available temperature range. The hot plate and the guard ring are sandwiched between two specimens of the

same

HAGENBACH CORRECTION Statistic Cookies . In order to continuously improve our website, we anonymously track data for statistical and analytical purposes. These cookies collect information about how visitors use a website, for instance which pages visitors go to most often, and how visitors move

around the site.

FATIGUE TEST

Statistic Cookies . In order to continuously improve our website, we anonymously track data for statistical and analytical purposes. These cookies collect information about how visitors use a website, for instance which pages visitors go to most often, and how visitors move

around the site.

RABINOWITSCH CORRECTION The Rabinowitsch (or Weissenberg-Rabinowitsch) correction is applied to get more accurate shear rate values from non-Newtonian materials measured using a capillary flow technique.. The basic shear rate equation for capillary flow is based on Newtonian fluids, where the velocity profile from pressure-driven flow in a capillary is shown to be homogenous (parabolic); however, for non-Newtonian GABOMETER - NETZSCH ANALYZING & TESTING The testing instruments of the DMA GABO EPLEXOR ® series up to ±500 N enable the dynamic mechanical (or static) characterization of a wide range of different materials including elastomers and polymers, composites, metals, glasses, ceramics, biomaterials and foods, adhesives, and liquids. DMA GABO EPLEXOR ® Ultra-High Force Series up

to 6000 N.

LOI – OXYGEN INDEX ANALYZER Testing system for determining the burning behavior of plastics by oxygen index at ambient temperature in accordance with ISO 4589-2, DIN 22117 and ASTM D 2863. Compact and lightweight, the device features a high-resolution touch display for intuitive user guidance. The fully automatic calibration and testing functions make it easy to operate DYNAMIC MECHANICAL ANALYSIS (DMA) Dynamic Mechanical Analysis (DMA) is an indispensable tool for determining the visco-elastic properties of materials, mainly polymers. Elastomers, for example, are very rigid below the glass transition temperature (T g) and have a high modulus of elasticity. Above T g, they are flexible and show damping performance.DMA measures the visco-elastic properties during a controlled temperature and LASER FLASH TECHNIQUE (LFA) The LFA 457 MicroFlash ® is the most modern product for the determination of the two thermophysical properties, thermal diffusivity and conductivity, in the range from -125°C to 1100°C. Its compact, vacuum-tight construction, automatic sample changer and functional software guarantee the highest effectiveness for challenging materials testing. DIL 402 EXPEDIS SELECT & SUPREME The dilatometer DIL 402 Expedis Select and Supreme offer state-of-the-art dilatometer technology and are designed for a wide range of sophisticated applications. All instruments of the DIL Expedis series feature the revolutionary NanoEye measuring cell; a new dimension in measuring range and accuracy.. It is the first horizontal dilatometer series on the market which allows for force

DSC 3500 SIRIUS

NETZSCH is the leading manufacturer of high quality DSC instruments or Differential Scanning Calorimeters at attractive prices with easy handling and advanced Software. The cost-effective starter instrument for material characterization. The DSC 3500 Sirius unites state-of-the-art technology with high sensitivity in a robust, easy-to-operate measuring system across a temperature range from

ROSAND RH2000

The Rosand RH2000 capillary rheometer system enables controlled extrusion (by volumetric flow) of a sample through a high precision die of known dimensions, to characterize material flow properties typically under conditions of high force (or pressure) and/or high shear rate. Using the twin bore barrel option and a ‘zero length’

die

TG 209 F3 TARSUS®

TG 209 F3 Tarsus - this easy-to-use thermo-microbalance was developed especially for routine applications in the field of plastics, but also for the chemical industry. It is the ideal starter unit up to 1000°C and, together with the DSC 200 F3 Maia®, represents a cost-effective

overall concept.

GUARDED HOT PLATE (GHP) The Guarded Hot Plate instrument measures the thermal conductivity of insulation products. The GHP principle is based on an absolute measurement method and therefore requires no calibration standards. It offers optimum accuracy in the available temperature range. The hot plate and the guard ring are sandwiched between two specimens of the

same

DEGREE OF CURE

This can easily be measured by means of differential scanning calorimetry (DSC). The degree of curing, α, is the amount of heat converted divided by the reaction enthalpy. α = H/ΔH R. The degree of cure of an already (partially) crosslinked sample can be determined GABOMETER - NETZSCH ANALYZING & TESTING The testing instruments of the DMA GABO EPLEXOR ® series up to ±500 N enable the dynamic mechanical (or static) characterization of a wide range of different materials including elastomers and polymers, composites, metals, glasses, ceramics, biomaterials and foods, adhesives, and liquids. DMA GABO EPLEXOR ® Ultra-High Force Series up

to 6000 N.

LOI – OXYGEN INDEX ANALYZER Testing system for determining the burning behavior of plastics by oxygen index at ambient temperature in accordance with ISO 4589-2, DIN 22117 and ASTM D 2863. Compact and lightweight, the device features a high-resolution touch display for intuitive user guidance. The fully automatic calibration and testing functions make it easy to operate DYNAMIC MECHANICAL ANALYSIS (DMA) Dynamic Mechanical Analysis (DMA) is an indispensable tool for determining the visco-elastic properties of materials, mainly polymers. Elastomers, for example, are very rigid below the glass transition temperature (T g) and have a high modulus of elasticity. Above T g, they are flexible and show damping performance.DMA measures the visco-elastic properties during a controlled temperature and LASER FLASH TECHNIQUE (LFA) The LFA 457 MicroFlash ® is the most modern product for the determination of the two thermophysical properties, thermal diffusivity and conductivity, in the range from -125°C to 1100°C. Its compact, vacuum-tight construction, automatic sample changer and functional software guarantee the highest effectiveness for challenging materials testing. DIL 402 EXPEDIS SELECT & SUPREME The dilatometer DIL 402 Expedis Select and Supreme offer state-of-the-art dilatometer technology and are designed for a wide range of sophisticated applications. All instruments of the DIL Expedis series feature the revolutionary NanoEye measuring cell; a new dimension in measuring range and accuracy.. It is the first horizontal dilatometer series on the market which allows for force

DSC 3500 SIRIUS

NETZSCH is the leading manufacturer of high quality DSC instruments or Differential Scanning Calorimeters at attractive prices with easy handling and advanced Software. The cost-effective starter instrument for material characterization. The DSC 3500 Sirius unites state-of-the-art technology with high sensitivity in a robust, easy-to-operate measuring system across a temperature range from

ROSAND RH2000

The Rosand RH2000 capillary rheometer system enables controlled extrusion (by volumetric flow) of a sample through a high precision die of known dimensions, to characterize material flow properties typically under conditions of high force (or pressure) and/or high shear rate. Using the twin bore barrel option and a ‘zero length’

die

TG 209 F3 TARSUS®

TG 209 F3 Tarsus - this easy-to-use thermo-microbalance was developed especially for routine applications in the field of plastics, but also for the chemical industry. It is the ideal starter unit up to 1000°C and, together with the DSC 200 F3 Maia®, represents a cost-effective

overall concept.

GUARDED HOT PLATE (GHP) The Guarded Hot Plate instrument measures the thermal conductivity of insulation products. The GHP principle is based on an absolute measurement method and therefore requires no calibration standards. It offers optimum accuracy in the available temperature range. The hot plate and the guard ring are sandwiched between two specimens of the

same

DEGREE OF CURE

This can easily be measured by means of differential scanning calorimetry (DSC). The degree of curing, α, is the amount of heat converted divided by the reaction enthalpy. α = H/ΔH R. The degree of cure of an already (partially) crosslinked sample can be determined

DSC 3500 SIRIUS

NETZSCH is the leading manufacturer of high quality DSC instruments or Differential Scanning Calorimeters at attractive prices with easy handling and advanced Software. The cost-effective starter instrument for material characterization. The DSC 3500 Sirius unites state-of-the-art technology with high sensitivity in a robust, easy-to-operate measuring system across a temperature range from DIL 402 EXPEDIS SELECT & SUPREME The dilatometer DIL 402 Expedis Select and Supreme offer state-of-the-art dilatometer technology and are designed for a wide range of sophisticated applications. All instruments of the DIL Expedis series feature the revolutionary NanoEye measuring cell; a new dimension in measuring range and accuracy.. It is the first horizontal dilatometer series on the market which allows for force QMS 403 AËOLOS QUADRO The Fleshed-Out Design of the QMS 403 Aëolos Quadro for Coupling to TGA, STA, DSC and DIL Systems. The 403 Aëolos Quadro quadrupole mass spectrometer is a new compact mass spectrometer with a heated capillary inlet system for routine analysis of gases and, in particular, volatile decomposition products of thermal analysis. This system is optimized for coupling to differential scanning GUARDED HOT PLATE (GHP) The Guarded Hot Plate instrument measures the thermal conductivity of insulation products. The GHP principle is based on an absolute measurement method and therefore requires no calibration standards. It offers optimum accuracy in the available temperature range. The hot plate and the guard ring are sandwiched between two specimens of the

same

QUALITY CONTROL OF POLYMERS BY MEANS OF DSC Quality Control of Polymers by means of DSC - Thermal Behavior of Thermoplastic Polyurethane. This plot shows a measurement on TPU. During the 1 st heating, the endothermic step at -42°C (mid-point) reflects the glass transition of the soft segments of the sample.. Additionally, the curve exhibits an endothermic double peak between

100°C and 210°C.

EUTECTIC PURITY

Eutectic Purity: What is it? A eutectic system is a homogeneous mixture of 2 components that melts and solidifies like a pure substance. The presence of an additional component (“impurity”) causes the reduction of the melting point of the main component. This effect can be highlighted with differential scanning calorimetry (DSC).. For materials with a purity higher than 98.5 mol percent

DILATOMETRY (DIL)

Dilatometry is the method of choice to study length change phenomena of ceramics, glasses, metals, composites, and polymers as well as other construction materials, thus revealing information regarding their thermal behavior and about process parameters or sintering (and curing) kinetics. Lab Contact.

POLYCARBONATE

Polycarbonate — Thermal Conductivity. Polycarbonate (PC) is a popular polymer material used among other things, for electric tool casings. To optimize the production/molding process by finite element simulations, the thermophysical properties have to be known. The thermal diffusivity can be determined not only in the solid region but

also at

PHI-FACTOR - NETZSCH ANALYZING & TESTING PHI-factor. The PHI-factor (Φ) is equivalent to the thermal inertia. Both describe the ratio of mass and specific heat capacity of a sample or sample mixture compared to that of the vessel or sample container. The closer the PHI-factor is to 1, the lower the influence of the container and the more representative the result is of the sample

itself.

US PATENTS - NETZSCH ANALYZING & TESTING US Patents. NETZSCH makes every effort to protect our intellectual property – our new ideas and investments in innovation and creativity. Whether it is new products that have been invented or new uses for old ones discovered, we have filed for patents in the various countries around the world to promote stronger and more effective intellectual property protection around the world. GABOMETER - NETZSCH ANALYZING & TESTING The testing instruments of the DMA GABO EPLEXOR ® series up to ±500 N enable the dynamic mechanical (or static) characterization of a wide range of different materials including elastomers and polymers, composites, metals, glasses, ceramics, biomaterials and foods, adhesives, and liquids. DMA GABO EPLEXOR ® Ultra-High Force Series up

to 6000 N.

LOI – OXYGEN INDEX ANALYZER Testing system for determining the burning behavior of plastics by oxygen index at ambient temperature in accordance with ISO 4589-2, DIN 22117 and ASTM D 2863. Compact and lightweight, the device features a high-resolution touch display for intuitive user guidance. The fully automatic calibration and testing functions make it easy to operate DYNAMIC MECHANICAL ANALYSIS (DMA) Dynamic Mechanical Analysis (DMA) is an indispensable tool for determining the visco-elastic properties of materials, mainly polymers. Elastomers, for example, are very rigid below the glass transition temperature (T g) and have a high modulus of elasticity. Above T g, they are flexible and show damping performance.DMA measures the visco-elastic properties during a controlled temperature and DIL 402 EXPEDIS SELECT & SUPREME The dilatometer DIL 402 Expedis Select and Supreme offer state-of-the-art dilatometer technology and are designed for a wide range of sophisticated applications. All instruments of the DIL Expedis series feature the revolutionary NanoEye measuring cell; a new dimension in measuring range and accuracy.. It is the first horizontal dilatometer series on the market which allows for force LASER FLASH TECHNIQUE (LFA) The LFA 457 MicroFlash ® is the most modern product for the determination of the two thermophysical properties, thermal diffusivity and conductivity, in the range from -125°C to 1100°C. Its compact, vacuum-tight construction, automatic sample changer and functional software guarantee the highest effectiveness for challenging materials testing.

DSC 3500 SIRIUS

NETZSCH is the leading manufacturer of high quality DSC instruments or Differential Scanning Calorimeters at attractive prices with easy handling and advanced Software. The cost-effective starter instrument for material characterization. The DSC 3500 Sirius unites state-of-the-art technology with high sensitivity in a robust, easy-to-operate measuring system across a temperature range from

ROSAND RH2000

The Rosand RH2000 capillary rheometer system enables controlled extrusion (by volumetric flow) of a sample through a high precision die of known dimensions, to characterize material flow properties typically under conditions of high force (or pressure) and/or high shear rate. Using the twin bore barrel option and a ‘zero length’

die

GUARDED HOT PLATE (GHP) The Guarded Hot Plate instrument measures the thermal conductivity of insulation products. The GHP principle is based on an absolute measurement method and therefore requires no calibration standards. It offers optimum accuracy in the available temperature range. The hot plate and the guard ring are sandwiched between two specimens of the

same

TG 209 F3 TARSUS®

TG 209 F3 Tarsus - this easy-to-use thermo-microbalance was developed especially for routine applications in the field of plastics, but also for the chemical industry. It is the ideal starter unit up to 1000°C and, together with the DSC 200 F3 Maia®, represents a cost-effective

overall concept.

DEGREE OF CURE

This can easily be measured by means of differential scanning calorimetry (DSC). The degree of curing, α, is the amount of heat converted divided by the reaction enthalpy. α = H/ΔH R. The degree of cure of an already (partially) crosslinked sample can be determined GABOMETER - NETZSCH ANALYZING & TESTING The testing instruments of the DMA GABO EPLEXOR ® series up to ±500 N enable the dynamic mechanical (or static) characterization of a wide range of different materials including elastomers and polymers, composites, metals, glasses, ceramics, biomaterials and foods, adhesives, and liquids. DMA GABO EPLEXOR ® Ultra-High Force Series up

to 6000 N.

LOI – OXYGEN INDEX ANALYZER Testing system for determining the burning behavior of plastics by oxygen index at ambient temperature in accordance with ISO 4589-2, DIN 22117 and ASTM D 2863. Compact and lightweight, the device features a high-resolution touch display for intuitive user guidance. The fully automatic calibration and testing functions make it easy to operate DYNAMIC MECHANICAL ANALYSIS (DMA) Dynamic Mechanical Analysis (DMA) is an indispensable tool for determining the visco-elastic properties of materials, mainly polymers. Elastomers, for example, are very rigid below the glass transition temperature (T g) and have a high modulus of elasticity. Above T g, they are flexible and show damping performance.DMA measures the visco-elastic properties during a controlled temperature and DIL 402 EXPEDIS SELECT & SUPREME The dilatometer DIL 402 Expedis Select and Supreme offer state-of-the-art dilatometer technology and are designed for a wide range of sophisticated applications. All instruments of the DIL Expedis series feature the revolutionary NanoEye measuring cell; a new dimension in measuring range and accuracy.. It is the first horizontal dilatometer series on the market which allows for force LASER FLASH TECHNIQUE (LFA) The LFA 457 MicroFlash ® is the most modern product for the determination of the two thermophysical properties, thermal diffusivity and conductivity, in the range from -125°C to 1100°C. Its compact, vacuum-tight construction, automatic sample changer and functional software guarantee the highest effectiveness for challenging materials testing.

DSC 3500 SIRIUS

NETZSCH is the leading manufacturer of high quality DSC instruments or Differential Scanning Calorimeters at attractive prices with easy handling and advanced Software. The cost-effective starter instrument for material characterization. The DSC 3500 Sirius unites state-of-the-art technology with high sensitivity in a robust, easy-to-operate measuring system across a temperature range from

ROSAND RH2000

The Rosand RH2000 capillary rheometer system enables controlled extrusion (by volumetric flow) of a sample through a high precision die of known dimensions, to characterize material flow properties typically under conditions of high force (or pressure) and/or high shear rate. Using the twin bore barrel option and a ‘zero length’

die

GUARDED HOT PLATE (GHP) The Guarded Hot Plate instrument measures the thermal conductivity of insulation products. The GHP principle is based on an absolute measurement method and therefore requires no calibration standards. It offers optimum accuracy in the available temperature range. The hot plate and the guard ring are sandwiched between two specimens of the

same

TG 209 F3 TARSUS®

TG 209 F3 Tarsus - this easy-to-use thermo-microbalance was developed especially for routine applications in the field of plastics, but also for the chemical industry. It is the ideal starter unit up to 1000°C and, together with the DSC 200 F3 Maia®, represents a cost-effective

overall concept.

DEGREE OF CURE

This can easily be measured by means of differential scanning calorimetry (DSC). The degree of curing, α, is the amount of heat converted divided by the reaction enthalpy. α = H/ΔH R. The degree of cure of an already (partially) crosslinked sample can be determined DYNAMIC MECHANICAL ANALYSIS (DMA) Dynamic Mechanical Analysis (DMA) is an indispensable tool for determining the visco-elastic properties of materials, mainly polymers. Elastomers, for example, are very rigid below the glass transition temperature (T g) and have a high modulus of elasticity. Above T g, they are flexible and show damping performance.DMA measures the visco-elastic properties during a controlled temperature and QMS 403 AËOLOS QUADRO The Fleshed-Out Design of the QMS 403 Aëolos Quadro for Coupling to TGA, STA, DSC and DIL Systems. The 403 Aëolos Quadro quadrupole mass spectrometer is a new compact mass spectrometer with a heated capillary inlet system for routine analysis of gases and, in particular, volatile decomposition products of thermal analysis. This system is optimized for coupling to differential scanning GUARDED HOT PLATE (GHP) The Guarded Hot Plate instrument measures the thermal conductivity of insulation products. The GHP principle is based on an absolute measurement method and therefore requires no calibration standards. It offers optimum accuracy in the available temperature range. The hot plate and the guard ring are sandwiched between two specimens of the

same

DMA EPLEXOR® UP TO 6000 DMA GABO EPLEXOR. Ultra-High Force Series up to 6000 N. These instruments offer static and additional dynamic force levels from max. 2000 N to max. ± 6000 N each, and are thus the perfect choice for investigating the dynamic mechanical (or only static) properties of rigid samples as well as of specimens with larger dimensions – even

DEGREE OF CURE

This can easily be measured by means of differential scanning calorimetry (DSC). The degree of curing, α, is the amount of heat converted divided by the reaction enthalpy. α = H/ΔH R. The degree of cure of an already (partially) crosslinked sample can be determined

DSC 214 POLYMA

NETZSCH is the leading manufacturer of high quality DSC instruments or Differential Scanning Calorimeters at attractive prices with easy handling and advanced Software. The New All-Inclusive Product Package for DSC Measurements Easy-to-use, robust, precise, optimized for everyday use – these are the features of the innovative DSC 214

Polyma.

EUTECTIC PURITY

Eutectic Purity: What is it? A eutectic system is a homogeneous mixture of 2 components that melts and solidifies like a pure substance. The presence of an additional component (“impurity”) causes the reduction of the melting point of the main component. This effect can be highlighted with differential scanning calorimetry (DSC).. For materials with a purity higher than 98.5 mol percent

COMPLEX MODULUS

The complex modulus consists of two components, the storage and the loss moduli. The storage modulus (or Young’s modulus) describes the stiffness and the loss modulus describes the damping (or viscoelastic) behavior of the corresponding sample using the method of Dynamic Mechanical Analysis (DMA).The complex modulus is the sum of the storage and loss modulus where the loss modulus is

POLYCARBONATE

Polycarbonate — Thermal Conductivity. Polycarbonate (PC) is a popular polymer material used among other things, for electric tool casings. To optimize the production/molding process by finite element simulations, the thermophysical properties have to be known. The thermal diffusivity can be determined not only in the solid region but

also at

US PATENTS - NETZSCH ANALYZING & TESTING US Patents. NETZSCH makes every effort to protect our intellectual property – our new ideas and investments in innovation and creativity. Whether it is new products that have been invented or new uses for old ones discovered, we have filed for patents in the various countries around the world to promote stronger and more effective intellectual property protection around the world. GABOMETER - NETZSCH ANALYZING & TESTING The testing instruments of the DMA GABO EPLEXOR ® series up to ±500 N enable the dynamic mechanical (or static) characterization of a wide range of different materials including elastomers and polymers, composites, metals, glasses, ceramics, biomaterials and foods, adhesives, and liquids. DMA GABO EPLEXOR ® Ultra-High Force Series up

to 6000 N.

LOI – OXYGEN INDEX ANALYZER Testing system for determining the burning behavior of plastics by oxygen index at ambient temperature in accordance with ISO 4589-2, DIN 22117 and ASTM D 2863. Compact and lightweight, the device features a high-resolution touch display for intuitive user guidance. The fully automatic calibration and testing functions make it easy to operate DYNAMIC MECHANICAL ANALYSIS (DMA) Dynamic Mechanical Analysis (DMA) is an indispensable tool for determining the visco-elastic properties of materials, mainly polymers. Elastomers, for example, are very rigid below the glass transition temperature (T g) and have a high modulus of elasticity. Above T g, they are flexible and show damping performance.DMA measures the visco-elastic properties during a controlled temperature and DIL 402 EXPEDIS SELECT & SUPREME The dilatometer DIL 402 Expedis Select and Supreme offer state-of-the-art dilatometer technology and are designed for a wide range of sophisticated applications. All instruments of the DIL Expedis series feature the revolutionary NanoEye measuring cell; a new dimension in measuring range and accuracy.. It is the first horizontal dilatometer series on the market which allows for force LASER FLASH TECHNIQUE (LFA) The LFA 457 MicroFlash ® is the most modern product for the determination of the two thermophysical properties, thermal diffusivity and conductivity, in the range from -125°C to 1100°C. Its compact, vacuum-tight construction, automatic sample changer and functional software guarantee the highest effectiveness for challenging materials testing.

DSC 3500 SIRIUS

NETZSCH is the leading manufacturer of high quality DSC instruments or Differential Scanning Calorimeters at attractive prices with easy handling and advanced Software. The cost-effective starter instrument for material characterization. The DSC 3500 Sirius unites state-of-the-art technology with high sensitivity in a robust, easy-to-operate measuring system across a temperature range from

ROSAND RH2000

The Rosand RH2000 capillary rheometer system enables controlled extrusion (by volumetric flow) of a sample through a high precision die of known dimensions, to characterize material flow properties typically under conditions of high force (or pressure) and/or high shear rate. Using the twin bore barrel option and a ‘zero length’

die

GUARDED HOT PLATE (GHP) The Guarded Hot Plate instrument measures the thermal conductivity of insulation products. The GHP principle is based on an absolute measurement method and therefore requires no calibration standards. It offers optimum accuracy in the available temperature range. The hot plate and the guard ring are sandwiched between two specimens of the

same

TG 209 F3 TARSUS®

TG 209 F3 Tarsus - this easy-to-use thermo-microbalance was developed especially for routine applications in the field of plastics, but also for the chemical industry. It is the ideal starter unit up to 1000°C and, together with the DSC 200 F3 Maia®, represents a cost-effective

overall concept.

DEGREE OF CURE

This can easily be measured by means of differential scanning calorimetry (DSC). The degree of curing, α, is the amount of heat converted divided by the reaction enthalpy. α = H/ΔH R. The degree of cure of an already (partially) crosslinked sample can be determined GABOMETER - NETZSCH ANALYZING & TESTING The testing instruments of the DMA GABO EPLEXOR ® series up to ±500 N enable the dynamic mechanical (or static) characterization of a wide range of different materials including elastomers and polymers, composites, metals, glasses, ceramics, biomaterials and foods, adhesives, and liquids. DMA GABO EPLEXOR ® Ultra-High Force Series up

to 6000 N.

LOI – OXYGEN INDEX ANALYZER Testing system for determining the burning behavior of plastics by oxygen index at ambient temperature in accordance with ISO 4589-2, DIN 22117 and ASTM D 2863. Compact and lightweight, the device features a high-resolution touch display for intuitive user guidance. The fully automatic calibration and testing functions make it easy to operate DYNAMIC MECHANICAL ANALYSIS (DMA) Dynamic Mechanical Analysis (DMA) is an indispensable tool for determining the visco-elastic properties of materials, mainly polymers. Elastomers, for example, are very rigid below the glass transition temperature (T g) and have a high modulus of elasticity. Above T g, they are flexible and show damping performance.DMA measures the visco-elastic properties during a controlled temperature and DIL 402 EXPEDIS SELECT & SUPREME The dilatometer DIL 402 Expedis Select and Supreme offer state-of-the-art dilatometer technology and are designed for a wide range of sophisticated applications. All instruments of the DIL Expedis series feature the revolutionary NanoEye measuring cell; a new dimension in measuring range and accuracy.. It is the first horizontal dilatometer series on the market which allows for force LASER FLASH TECHNIQUE (LFA) The LFA 457 MicroFlash ® is the most modern product for the determination of the two thermophysical properties, thermal diffusivity and conductivity, in the range from -125°C to 1100°C. Its compact, vacuum-tight construction, automatic sample changer and functional software guarantee the highest effectiveness for challenging materials testing.

DSC 3500 SIRIUS

NETZSCH is the leading manufacturer of high quality DSC instruments or Differential Scanning Calorimeters at attractive prices with easy handling and advanced Software. The cost-effective starter instrument for material characterization. The DSC 3500 Sirius unites state-of-the-art technology with high sensitivity in a robust, easy-to-operate measuring system across a temperature range from

ROSAND RH2000

The Rosand RH2000 capillary rheometer system enables controlled extrusion (by volumetric flow) of a sample through a high precision die of known dimensions, to characterize material flow properties typically under conditions of high force (or pressure) and/or high shear rate. Using the twin bore barrel option and a ‘zero length’

die

GUARDED HOT PLATE (GHP) The Guarded Hot Plate instrument measures the thermal conductivity of insulation products. The GHP principle is based on an absolute measurement method and therefore requires no calibration standards. It offers optimum accuracy in the available temperature range. The hot plate and the guard ring are sandwiched between two specimens of the

same

TG 209 F3 TARSUS®

TG 209 F3 Tarsus - this easy-to-use thermo-microbalance was developed especially for routine applications in the field of plastics, but also for the chemical industry. It is the ideal starter unit up to 1000°C and, together with the DSC 200 F3 Maia®, represents a cost-effective

overall concept.

DEGREE OF CURE

This can easily be measured by means of differential scanning calorimetry (DSC). The degree of curing, α, is the amount of heat converted divided by the reaction enthalpy. α = H/ΔH R. The degree of cure of an already (partially) crosslinked sample can be determined DYNAMIC MECHANICAL ANALYSIS (DMA) Dynamic Mechanical Analysis (DMA) is an indispensable tool for determining the visco-elastic properties of materials, mainly polymers. Elastomers, for example, are very rigid below the glass transition temperature (T g) and have a high modulus of elasticity. Above T g, they are flexible and show damping performance.DMA measures the visco-elastic properties during a controlled temperature and QMS 403 AËOLOS QUADRO The Fleshed-Out Design of the QMS 403 Aëolos Quadro for Coupling to TGA, STA, DSC and DIL Systems. The 403 Aëolos Quadro quadrupole mass spectrometer is a new compact mass spectrometer with a heated capillary inlet system for routine analysis of gases and, in particular, volatile decomposition products of thermal analysis. This system is optimized for coupling to differential scanning GUARDED HOT PLATE (GHP) The Guarded Hot Plate instrument measures the thermal conductivity of insulation products. The GHP principle is based on an absolute measurement method and therefore requires no calibration standards. It offers optimum accuracy in the available temperature range. The hot plate and the guard ring are sandwiched between two specimens of the

same

DMA EPLEXOR® UP TO 6000 DMA GABO EPLEXOR. Ultra-High Force Series up to 6000 N. These instruments offer static and additional dynamic force levels from max. 2000 N to max. ± 6000 N each, and are thus the perfect choice for investigating the dynamic mechanical (or only static) properties of rigid samples as well as of specimens with larger dimensions – even

DEGREE OF CURE

This can easily be measured by means of differential scanning calorimetry (DSC). The degree of curing, α, is the amount of heat converted divided by the reaction enthalpy. α = H/ΔH R. The degree of cure of an already (partially) crosslinked sample can be determined

DSC 214 POLYMA

NETZSCH is the leading manufacturer of high quality DSC instruments or Differential Scanning Calorimeters at attractive prices with easy handling and advanced Software. The New All-Inclusive Product Package for DSC Measurements Easy-to-use, robust, precise, optimized for everyday use – these are the features of the innovative DSC 214

Polyma.

EUTECTIC PURITY

Eutectic Purity: What is it? A eutectic system is a homogeneous mixture of 2 components that melts and solidifies like a pure substance. The presence of an additional component (“impurity”) causes the reduction of the melting point of the main component. This effect can be highlighted with differential scanning calorimetry (DSC).. For materials with a purity higher than 98.5 mol percent

COMPLEX MODULUS

The complex modulus consists of two components, the storage and the loss moduli. The storage modulus (or Young’s modulus) describes the stiffness and the loss modulus describes the damping (or viscoelastic) behavior of the corresponding sample using the method of Dynamic Mechanical Analysis (DMA).The complex modulus is the sum of the storage and loss modulus where the loss modulus is

POLYCARBONATE

Polycarbonate — Thermal Conductivity. Polycarbonate (PC) is a popular polymer material used among other things, for electric tool casings. To optimize the production/molding process by finite element simulations, the thermophysical properties have to be known. The thermal diffusivity can be determined not only in the solid region but

also at

US PATENTS - NETZSCH ANALYZING & TESTING US Patents. NETZSCH makes every effort to protect our intellectual property – our new ideas and investments in innovation and creativity. Whether it is new products that have been invented or new uses for old ones discovered, we have filed for patents in the various countries around the world to promote stronger and more effective intellectual property protection around the world. * Literature & Digital Media

* Glossary

* Newsletter

* About NETZSCH

* Careers

* About NETZSCH

* Locations

*

English

* English

* Deutsch

* English (Australia)

* English (US)

* Español

* Français

* Italiano

* 日本語

* 한국어

* Polski

* Português

* Pусский

* Türkçe

* Contact

* Locations

*

* Products & Solutions Fire Testing Rheology Differential Scanning Calorimetry Thermogravimetric Analysis

Simultaneous

Thermogravimetry - Differential Scanning Calorimetry Dilatometry Thermomechanical

Analysis Dynamic

Mechanical Analysis

Multiple Module

Calorimeter

Accelerating Rate Calorimetry

Dielectric

Analysis (incl. sensXPERT Solution) Thermal Diffusivity & Conductivity

Thermal

Conductivity Hyphenated Techniques - Evolved Gas Analysis

Refractory Testing

Software

* Materials & Applications

Pharma Polymers

Ceramics & Glass

Metals & Alloys

Thermoelectric

Organics

Inorganics

Adhesives & Sealants

Thermal Insulation

Photovoltaics

Batteries

Building Materials

Biomass

* Events & Seminars

* Service & Support

FAQ Service Technical Service

Training & Seminars

Repair Service

On-Site Service

Application Measurements Applications Advisory

Service Service

in Regulated Areas

Customer Magazine onset Newsletter Service Service

Contact Form

Certificates Material Safety Data

Sheets

* Contract Testing

Glossary Methods

*

*

*

*

*

COEFFICIENT OF THERMAL EXPANSION: A CRUCIAL MATERIAL PROPERTY The design of parts and components made of fiber-reinforced composites needs to take the coefficient of thermal expansion into account because it determines the extent to which a material changes its dimensions when heated or cooled. Thermomechanical Analysis is the perfect method to predict product performance and processing behavior. Read our contribution to the journal _Kunststoffe International_ for an overview of applications.

Read more...

WHY NETZSCH HEAT FLOW METERS SUPPORT REDUCTION OF C02 EMISSIONS Governments set strict building insulation regulations in place to reduce carbon emissions. Consequently, a lot of effort goes into the engineering of materials with very low thermal conductivity to supply the market with even better thermal insulation materials. Learn how the NETZSCH HFM 446 Lambda Eco-Line allows accurate and fast determination of thermal conductivity and thermal resistance!

Read more...

RHEOLOGY: THE REASON FOR BEAUTIFUL NAILS In the last few years, the nail polish industry has really opened up its beauty box of tricks and on the market today. Surely there must be some exciting science behind it all? Learn about curing and the influence of pigment – all measured with a Kinexus Rotational

Rheometer!

Read more...

------------------------- JOIN OUR FREE WEBINARS

Webinar 08 Jun 2021

Talking to the experts- Efficient determination of thermal conductivity on insulation materials

Germany

Webinar 17 Jun 2021, 05:00 pm – 06:00 pm NETZSCH interviews AM Experts: Understanding Material Properties for Industrial Material Extrusion

Germany

Webinar 22 Jul 2021, 05:00 pm – 06:00 pm NETZSCH interviews AM experts: Digital Light Synthesis of UV-Curable

Materials

Germany

Webinar 30 Sep 2021

NETZSCH interviews AM Experts: UV-Curable Resins - Using FT-IR Spectroscopy to Study Their Cure

Germany

FEATURED NETZSCH INSTRUMENTS HFM 446 Lambda Eco-Line The new HFM 446 Lambda Eco-Line features a standardized method for the measurement of thermal conductivity which is equally applicable in research and development and in quality assurance. TCC 918 – Cone Calorimeter Determination of the heat release rate, the dynamic smoke production and the mass-loss rate of specimens in horizontal orientation in accordance with to ISO 5660-1 TMA 402 _F3 Hyperion_® Polymer Edition - Tailor-made for low-temperature applications The TMA 402 _F3 Hyperion_® Polymer Edition was designed to gain valuable information about product performance and processing behavior of polymers. Equipped with the compact highly reactive IC-furnace, it covers a temperature range of -70°C to 450°C without the need of

LN2.

Rosand RH2000

Rosand RH2000 - Bench top capillary rheometer for research to QC

testing.

Products & Solutions Products & Solutions Products & Solutions Fire Testing Rheology Differential Scanning Calorimetry Thermogravimetric Analysis

Simultaneous

Thermogravimetry - Differential Scanning Calorimetry Dilatometry Thermomechanical

Analysis Dynamic

Mechanical Analysis

Multiple Module

Calorimeter

Accelerating Rate Calorimetry

Dielectric

Analysis (incl. sensXPERT Solution) Thermal Diffusivity & Conductivity

Thermal

Conductivity Hyphenated Techniques - Evolved Gas Analysis

Refractory Testing

Software Materials & Applications Materials & Applications Materials & Applications

Pharma

Polymers

Ceramics & Glass

Metals & Alloys

Thermoelectric

Organics

Inorganics

Adhesives & Sealants

Thermal Insulation

Photovoltaics

Batteries

Building Materials

Biomass

Events & Seminars

Service & Support

Service & Support Service & Support FAQ Service Technical Service

Training & Seminars

Repair Service

On-Site Service

Application Measurements Applications Advisory

Service Service

in Regulated Areas

Customer Magazine onset Newsletter Service Service

Contact Form

Certificates Material Safety Data

Sheets Contract

Testing

Contract Testing Contract Testing Glossary

Methods

Literature & Digital Media Literature & Digital Media Literature & Digital Media

Glossary

Newsletter

About NETZSCH

About NETZSCH About NETZSCH Careers

About NETZSCH

Locations

Contact

Contact Contact

Locations

------------------------- English Deutsch English (Australia) English (US) Español Français Italiano 日本語 한국어 Polski Português Pусский Türkçe NETZSCH Group NETZSCH Analyzing & Testing NETZSCH Pumps & Systems NETZSCH Grinding & Dispersing WE VALUE YOUR PRIVACY We use cookies in order to design our websites optimally for you. Some of them are technically necessary, while others help us to improve this website and your experience. You are free to decide which categories you would like to permit. Please note that depending on the settings you choose, the full functionality of the website may no longer be available. Further information can be found under Cookie

Details .

Accept all cookies

Manage cookie settings MANAGE COOKIE SETTINGS STRICTLY NECESSARY COOKIES These cookies are essential in order to enable you to move around the website and use its features, such as setting your privacy preferences, logging in or filling in forms. Without these cookies, services requested through usage of our website cannot be properly

provided.

STATISTIC COOKIES

In order to continuously improve our website, we anonymously track data for statistical and analytical purposes. These cookies collect information about how visitors use a website, for instance which pages visitors go to most often, and how visitors move around the site. They help us to improve the user friendliness of a website and therefore enhance the user’s experience. Confirm my selection Accept all cookies

* Cookie Details

* Data Protection Policy

* Imprint

ABOUT NETZSCH

* Company

* News

CAREER

* Jobs

NETZSCH WEBSITES

* NETZSCH Group

* NETZSCH Pumps & Systems * NETZSCH Grinding & Dispersing

CONTACT

NETZSCH-Gerätebau GmbH Wittelsbacherstraße 42

95100 Selb

Germany

Phone: (+49) 9287/881-0 Fax: (+49) 9287/881-505

at@netzsch.com

-------------------------

* Contact

* Sitemap

* Privacy Policy

* Company Info / Legal Notice

* Certificates

* Newsletter

* Local Contact

* Contact

* Service

* Digital Media

Details

2

Copyright © 2023 ArchiveBay.com. All rights reserved. Terms of Use | Privacy Policy | DMCA | 2021 | Feedback | Advertising | RSS 2.0